Abstract
Differentiating cardiogenic pulmonary oedema (CPE) from non-cardiogenic and
structurally normal lungs in lung ultrasound (LUS) videos remains challenging
due to the high visual variability of non-cardiogenic inflammatory patterns
(NCIP/ARDS-like), interstitial lung disease, and healthy lungs. This
heterogeneity complicates automated classification as overlapping B-lines and
pleural artefacts are common. We introduce ZACH-ViT (Zero-token Adaptive
Compact Hierarchical Vision Transformer), a 0.25 M-parameter Vision Transformer
variant that removes both positional embeddings and the [CLS] token, making it
fully permutation-invariant and suitable for unordered medical image data. To
enhance generalization, we propose ShuffleStrides Data Augmentation (SSDA),
which permutes probe-view sequences and frame orders while preserving
anatomical validity. ZACH-ViT was evaluated on 380 LUS videos from 95
critically ill patients against nine state-of-the-art baselines. Despite the
heterogeneity of the non-cardiogenic group, ZACH-ViT achieved the highest
validation and test ROC-AUC (0.80 and 0.79) with balanced sensitivity (0.60)
and specificity (0.91), while all competing models collapsed to trivial
classification. It trains 1.35x faster than Minimal ViT (0.62M parameters) with
2.5x fewer parameters, supporting real-time clinical deployment. These results
show that aligning architectural design with data structure can outperform
scale in small-data medical imaging.